Stair landing layout calculator

Plan two flights with uniform risers, landing elevation, straight/L/U footprint and downloadable diagrams.

Calculate the layout, check the diagram, then print the result for the shop or jobsite.

mm
mm
mm
mm
mm
Uniform riser height175mm
Individual treads excluding platforms14
First-flight run1750mm
Second-flight run1750mm
Landing elevation1400mm
Plan footprint width2000mm
Plan footprint depth2750mm

Step and platform elevations

Riser numberLevel typeElevation (mm)
1Tread175
2Tread350
3Tread525
4Tread700
5Tread875
6Tread1050
7Tread1225
8Intermediate landing1400
9Tread1575
10Tread1750
11Tread1925
12Tread2100
13Tread2275
14Tread2450
15Tread2625
16Upper floor2800

How it works

Riser height is total floor-to-floor rise divided by the entered total riser count. Each flight has one fewer individual tread than risers because its landing or upper floor provides the final surface. For 2800 mm rise and two flights of eight risers, risers are 175 mm, each flight has seven 250 mm goings and the intermediate landing is 1400 mm above the lower floor.

Current-input example

The result above uses these exact values. This snapshot is included when the page is printed so the output can be checked against the original measurements.

Total floor-to-floor rise
2800 mm
Total riser count
16
First-flight riser count
8
Going per tread
250 mm
Flight width
1000 mm
Landing width
2000 mm
Landing depth
1000 mm
Flight arrangement
Half-turn return landing

Primary result: Uniform riser height: 175 mm.

Before using the result

  • Measure from the datum or reference edge described by this tool, and do not mix inside, outside and centerline dimensions.
  • Keep inputs in the displayed units and preserve more precision than the final cutting or purchasing tolerance requires.
  • When the result is close to a limit, verify it with a test piece, field measurement, manufacturer drawing or qualified project professional.

Limitations

Plan geometry only. Landing dimensions are entered, not selected from a building code. A return layout requires room for two flight widths; any remaining width is the central gap. Floor openings, headroom, nosings, finish thickness, guardrails, structural members and local accessibility requirements are not checked. PDF/SVG output is a schematic, not a full-size cutting template.

Frequently asked questions

What should I verify before using this result?

Recheck the physical measurements, confirm that every input uses the displayed unit, and compare the result with the applicable drawing, product specification, code requirement or test piece.

Why might the finished result differ?

Real work can include thickness, kerf, seams, tolerances, hardware allowances, installation clearances or site conditions that are outside the calculation. The limitations section identifies the main exclusions for this tool.