Herramientas prácticas para trabajos de precisión
Verificador de Abertura y Holgura de Giro de Puerta para Lavavajillas
Verifique las holguras del cuerpo del lavavajillas y de la puerta completamente abierta contra el pasillo disponible.
Installation fit and door-swing clearance are checked independently.
How it works
The body check compares the required clearances with the opening. The swing check compares the horizontal reach of the fully open door and handle with the unobstructed aisle.
Current-input example
The result above uses these exact values. This snapshot is included when the page is printed so the output can be checked against the original measurements.
- Opening width
- 24 in
- Opening height
- 35 in
- Opening depth
- 24 in
- Dishwasher width
- 23.5 in
- Dishwasher height
- 34 in
- Dishwasher depth
- 23 in
- Left clearance
- 0.25 in
- Right clearance
- 0.25 in
- Top clearance
- 0.5 in
- Rear clearance
- 0.5 in
- Open door reach
- 27 in
- Handle projection
- 1 in
- Clear aisle depth
- 36 in
Primary result: Overall result: Fits.
Before using the result
- Measure from the datum or reference edge described by this tool, and do not mix inside, outside and centerline dimensions.
- Keep inputs in the displayed units and preserve more precision than the final cutting or purchasing tolerance requires.
- When the result is close to a limit, verify it with a test piece, field measurement, manufacturer drawing or qualified project professional.
Limitations
Use the exact product installation drawing. This does not check leveling range, hoses, plumbing, electrical, countertop attachment, adjacent drawer pulls or accessibility/code clearances.
Frequently asked questions
What should I verify before using this result?
Recheck the physical measurements, confirm that every input uses the displayed unit, and compare the result with the applicable drawing, product specification, code requirement or test piece.
Why might the finished result differ?
Real work can include thickness, kerf, seams, tolerances, hardware allowances, installation clearances or site conditions that are outside the calculation. The limitations section identifies the main exclusions for this tool.