Praktische Tools für exaktes Arbeiten
Rechner für Akustikpaneel-Fläche
Vergleichen Sie die Sichtfläche der Paneele und die geschätzte Absorption mit der Raumoberfläche anhand eines von Ihnen eingegebenen Referenzziels.
Effective coverage multiplies panel face area by the entered absorption coefficient. Use the coefficient for the frequency band that matters, not a marketing average.
How it works
How to use it: enter the room dimensions, subtract openings, then enter a reference coverage percentage and one panel size. The percentage is a quantity comparison, not a treatment prescription.
Formula. Panel count = ceiling(net room surface x target / panel effective area).
Example. A 0.6 by 1.2 m panel with coefficient 0.85 contributes 0.612 metric sabins.
Current-input example
The result above uses these exact values. This snapshot is included when the page is printed so the output can be checked against the original measurements.
- Room length
- 5.5 m
- Room width
- 4.2 m
- Room height
- 2.7 m
- Doors/windows
- 4 m²
- Effective coverage
- 20 %
- Panel width
- 0.6 m
- Panel height
- 1.2 m
- Absorption coefficient
- 0.85
Primary result: Panels for entered target: 31.
Before using the result
- Measure from the datum or reference edge described by this tool, and do not mix inside, outside and centerline dimensions.
- Keep inputs in the displayed units and preserve more precision than the final cutting or purchasing tolerance requires.
- When the result is close to a limit, verify it with a test piece, field measurement, manufacturer drawing or qualified project professional.
Limitations
Coverage percentage is a materials estimate, not an acoustic diagnosis. Panel placement, thickness, air gap, scattering, bass trapping and frequency-specific coefficients determine performance. Do not cover reflective surfaces blindly.
Frequently asked questions
Should floors and ceilings count?
They are included in gross surface area. If you only plan to treat walls, set a target with that practical scope in mind and use the result as a quantity comparison.
Verwandte Tools
Reflexionspunkte
Ermitteln Sie symmetrische Erstreflexionspunkte an den Seitenwänden mit der Spiegelquellenmethode und realen Raumkoordinaten.
RT60-Rechner
Schätzen Sie die Nachhallzeit nach Sabine und die insgesamt nötige Absorption für ein editierbares Abklingziel.
USV-Laufzeit
Schätzen Sie die Laufzeit aus der gesamten Akkukapazität und der gemessenen Rack-Last und prüfen Sie dabei sowohl die Watt- als auch die VA-Nennleistung der USV.
Sichtlinien
Schätzen Sie die für jede Sichtlinie nötige Reihenhöhe, um eine angenommene Kopfhöhe in der Reihe davor frei zu überblicken.