Ruimtemodus & Staande Golf Calculator
Somt axiale, tangentiële en schuine ruimteresonanties op en toont clusters van dicht bij elkaar liggende lage frequenties.
Red lines are axial modes, blue tangential, and grey oblique. Closely spaced modes can reinforce one another, but room response also depends on boundaries and placement.
How it works
How to use it: enter internal room dimensions and the mode order to enumerate. The chart sorts every axial, tangential and oblique resonance below your chosen frequency ceiling.
Formula. f = c/2 x sqrt((n/L)^2 + (m/W)^2 + (p/H)^2), using 343 m/s for sound speed. One non-zero index is axial, two tangential and three oblique.
Example. A 5.5 m room has its first length axial mode near 343/(2 x 5.5) = 31.2 Hz.
Current-input example
The result above uses these exact values. This snapshot is included when the page is printed so the output can be checked against the original measurements.
- Room length
- 5.5 m
- Room width
- 4.2 m
- Room height
- 2.7 m
- Mode order
- 4
- Chart maximum
- 200 Hz
Primary result: 1,0,0 axial: 31.2 Hz.
Before using the result
- Measure from the datum or reference edge described by this tool, and do not mix inside, outside and centerline dimensions.
- Keep inputs in the displayed units and preserve more precision than the final cutting or purchasing tolerance requires.
- When the result is close to a limit, verify it with a test piece, field measurement, manufacturer drawing or qualified project professional.
Limitations
Rectangular rigid-boundary theory predicts modal frequencies, not exact peak/null severity. Openings, wall flex, furnishings, temperature, source/listener placement and damping change measured response. Verify with room measurements before buying treatment.
Frequently asked questions
Are axial modes most important?
They involve one room dimension and are often stronger, but tangential and oblique modes still contribute to the measured response.
Gerelateerde tools
Scherm Gain
Bereken de benodigde schermgain of geleverde lumens voor een helderheidsdoel en vergelijk veelgebruikte gain-waarden.
UPS Overbruggingstijd
Schat de overbruggingstijd op basis van de totale accucapaciteit en gemeten rackbelasting, met controle van zowel het UPS-wattage als het VA-vermogen.
Zichtlijnen Zitplaatsen
Schat de rijverhoging die nodig is per zichtlijn om over een aangenomen hoofdhoogte in de rij ervoor heen te kunnen kijken.
Buitenbioscoop Scherm
Vergelijk kijkhoeken voor dichtbij en ver weg zittend publiek met schermafmetingen, formaatgrenzen en ideale helderheid voor een donker scherm.