Calculadora de RT60 y Tiempo de Reverberación

Estime el tiempo de reverberación de Sabine y la absorción total necesaria para un objetivo de decaimiento editable.

m
m
m
sabins
s
Estimated RT600.29s
Room volume62.4m3
Absorption for 0.40 s25.1sabins
Additional absorption0.0sabins

A metric sabin is one square metre of perfectly absorbing surface. Real materials contribute area multiplied by their frequency-dependent absorption coefficient.

Cómo funciona

How to use it: enter internal room dimensions and estimated total absorption at the frequency band of interest. Set a target to estimate how much absorption that target requires.

Formula. Sabine RT60 = 0.161 x room volume / total absorption.

Example. A 62.4 m3 room with 35 sabins has an estimated RT60 of 0.29 seconds.

Ejemplo con los datos actuales

El resultado anterior utiliza exactamente estos valores. Esta captura se incluye al imprimir para cotejar la salida con las medidas originales.

Room length
5.5 m
Room width
4.2 m
Room height
2.7 m
Total absorption
35 sabins
Target RT60
0.4 s

Resultado principal: Estimated RT60: 0.29 s.

Antes de usar el resultado

  • Measure from the datum or reference edge described by this tool, and do not mix inside, outside and centerline dimensions.
  • Keep inputs in the displayed units and preserve more precision than the final cutting or purchasing tolerance requires.
  • When the result is close to a limit, verify it with a test piece, field measurement, manufacturer drawing or qualified project professional.

Limitaciones

Sabine assumes a diffuse sound field and reasonably even absorption. Small rooms, sparse treatment, low frequencies and highly absorptive rooms can depart substantially. Use band-specific material data and confirm with a calibrated decay measurement.

Preguntas frecuentes

What RT60 should a home theater have?

There is no single universal target. Room size, listening use and measurement band matter, so compare against a considered design target rather than treating one number as a pass or fail.